Télécharger Imprimer la page

WIKA C-10 Mode D'emploi page 7

Masquer les pouces Voir aussi pour C-10:

Publicité

Specifications
Pressure ranges
Over pressure safety
Burst pressure
Pressure ranges
Over pressure safety
Burst pressure
Materials
n
Wetted parts
n
Case
Internal transmission fluid
Hilfsenergie U
B
Response time (10 ... 90 %)
*)
Accuracy
included Hysteresis
Repeatability
1-year stability
Permissible temperature of
n
Medium
n
Ambient
n
Storage
n
Compensated
Temperature coefficients in
compensated temp range
n
Mean TC of zero
n
Mean TC of range
a- conformity
Shock resistance
Vibration resistance
Wiring protection
Ingress protection per
Weight
1)
Media temperature for oxygen version: -30 ... +60 °C (-22 ... 140 °F).
Cannot be manufactured for absolute pressure ranges < 1 bar abs.
*)
Including linearity, hysteresis and reproducibility.
Limit point calibration in vertical mounting position with lower pressure connection.
{ }
Items in curved brackets { } are optional extras for additional price.
Model C-10
bar
0.25 0.4
0.6
bar
2
2
4
bar
2.4
2.4
4.8
bar
25
40
60
bar
50
80
120
bar
250
400
550
{Absolute pressure: 0 ... 0.25 bar abs to 0 ... 16 bar abs}
{Special pressure range 800 ... 1200 mbar abs}
Stainless steel
Stainless steel
Synthetic oil, only for pressure ranges up to 0 ... 16 bar
{Halocarbon oil for oxygen applications}
10 < U
≤ 30 (14 ... 30 with signal output 0 ... 10 V)
DC V
B
ms
< 1 (< 10 ms at medium temperatures below -30 °C
for pressure ranges up to 16 bar)
≤ 1.0
% of span
(limit point calibration)
≤ 0.5
% of span
(BFSL)
≤ 0.05
% of span
≤ 0.2
% of span
(at reference conditions)
-30 ... +100 °C {-40...+125°C} -22 ... +212 °F {-40 ... +257°F}
-30 ... + 85 °C
-40 ... +100 °C
0 ... + 80 °C
≤ 0.3 / 10 K
% of span
≤ 0.2 / 10 K
% of span
89/336/EWG interference emission and immunity see EN 61326
97/23/EG Pressure equipment directive, Appendix 1
g
1000 according to IEC 60068-2-27 (mechanical shock)
g
20 according to IEC 60068-2-6 (vibration under resonance)
Protected against reverse polarity, overvoltage and
short circuiting
Per IEC 60529 / EN 60529, see section 3, Installation
kg
Approx. 0.1
1
1.6
2.5
4
6
10
5
10
10
17
35
35
6
12
12
20.5 42
42
100
160
250
400
600
1000
200
320
500
800
1200 1500
800
1000 1200 1700 2400 3000
1)
-22 ... +185 °F
-40 ... +212 °F
32 ... +176 °F
16
80
96

Publicité

loading