Aqua Medic PERCULA 100 Mode D'emploi page 21

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

4.6. Parts of the venturi pump
Fig. 4: Venturi pump AQ 1200
1.
Engine block
2.
O-Ring
3.
Pressure connection fitting
4.
Rubber bearing and washer
5.
Ceramic shaft
6.
Rotor
7.
Mesh wheel
8.
Pump lock incl. O-Ring
9.
Air intake socket
10.
O-Ring
11.
Air intake nozzle
12.
Reduction
13.
Bayonet lock
4.7. Maintenance
The collection cup should be cleaned regularly (daily or weekly, depending on organic load). The
reaction pipe of the skimmer needs to be cleaned only once or twice a year. The venturi pump
should be cleaned at the same time. The pump has to be removed and the complete pump housing
and mesh wheel flushed with clean water. The same procedure should be done with the air
injection nozzle.
4.8. Problems
Problems may arise if the ration of drawn air and water is not correct.
The reasons could be:
-
Air intake nozzle, hose connection or hose is clogged or calcified.
Measure: Remove and clean it thoroughly.
21

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Percula 125 t5

Table des Matières