Aqua Medic PERCULA 100 Mode D'emploi page 23

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

5.3. Technical data, table 1
Type:
Pump voltage:
Power uptake, watts:
Voltage transformer:
Max. l/h:
Min. l/h:
Cable length in m: Pump:
Transformer:
Class/protection rating:
Max depth:
Max. media temperature:
Adjustment at the transformer:
The flow rate can be adjusted at the transformer to the level 6 / 9 / 12 V. When operating at 6 V,
we recommend firstly to select 9 or 12 V and then re-set to 6 V.
The pump is open at the front. Therefore, it should never be started uncontrolled, e. g.
via a timer. Animals could be in the sucking in basket and they could be injured or killed by the
starting propeller.
5.4. Exploded parts diagram
Fig. 5: Structure NanoProp 5000
1.
Filter basket
2.
Rotor assembly
3.
Motor housing
5.5. Set Up
The pump can only be operated under water. The maximum depth is 1 m. The pump should be
mounted at least 10 cm below the water surface to avoid air to be sucked in. The pump is a pure
current pump. No piping or hoses may be attached to it in order to lift water up.
NanoProp 5000
6 – 12 V DC
4 – 7 watts
100 – 240 V, 50 – 60 Hz
5,000
2,000
2.80
1.50
1/ IP 68
1 m
1m
35° C
23