Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

USER'S MANUAL MC-577.
[19]
SHORT
Luminous indicator showing over-consumption by the external unit or short
circuit.
[20]
RF
Satellite IF RF input and external unit powering (LNB) 0/13/18 V + 22 kHz
DRAIN
[21]
Luminous indicator showing the external unit normal consumption.
[22]
12V
Input of an external DC power supply with the pole corresponding to (+) on
central conductor and an input range from 11 V to 18 V, 1.2 A only for battery
charging. (In this situation, the MC-577 level meter can not be operative).
[23]
Digital frequency counter display
Digital presentation of the tuned frequency in MHz. In the maximum bandwidth
spectrum analyser operating mode (MAX) the digital frequency presentation is
inhibited.
SPAN
[24]
(Operational only in the variable bandwidth Spectrum Analyser mode -SPAN-).
Defines the frequency bandwidth to be shown
[25]
TUNING
Tuning control.
[26]
TV / TUNING
Tuning control of the audio carrier:
Terrestrial bands
Released control:
Pressed control:
Satellite band:

FINE TUNING

[27]
Fine tuning control.
[28]
Audio control and activation of the measurement information over the image:
Released control:
Pressed control:
05/2003
Sound corresponds to the internal filter according to
CCIR standard.
Variable tuning between 4.5 and 6.5 MHz for the
various TV standards, except standard L and in version
MC-577/1, TV standard M/N
Variable tuning between 5 and 8 MHz irrespective of
whether pressed or released
Selects the acoustic signal to represent the level, the tone
of which varies with the power received, also:
In Monitor mode it activates the measurement bar and the
representation of the synchronism pulse.
In Spectrum Analyser mode, SPAN mode, it activates the
C/N measurement bar.
Selects television sound demodulation, permits the volume
to be altered, and eliminates the measurement information
from the monitor.