How to proceed:
 M
1. Remove the container cover.
– The filter drum is stopped for safety reasons if the filter cover is lifted and Er11 is indicated in the
display of the control system.
2. Switch off the filter pump.
3. Switch off the mains voltage (ensure that the control system is isolated).
4. Alter the position of the holder in the filter container (see table).
– Undo and remove both screws of the holder. Push the holder into the correct position and fasten
with both screws.
5. Fit the container cover.
6. Switch on the control system and filter pumps and check the function of the status detection.
Position of the status detection
5
4
1)
3
2
1
1)
Factory setting
Triggering of the status detection at
Max. flow rate (12500 l/h) and the water runs over the inner cover
100 % water level
75 % water level
50 % water level
25 % water level
- EN -