Screen Messages - ZUMEX Essential Manuel De L'utilisateur

Masquer les pouces Voir aussi pour Essential:
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

Fault
Possible cause
The faucet gets blocked
The juice has seeds or too much
pulp.
The machine stops every
Insufficient ventilation.
now and again
Overload.
Screen does not display
Alteration to mains systems.
information
The machine is in self-
Faucet not fitted or fitted
service mode and won't
incorrectly.
stop operating
Faucet well fitted: possible
internal fault.
Faucet block activated.
The sweeper motor does
Pulp-out deactivated
not turn
Check that the PulpOut system
is active
WARNING:
Any action to unblock the machine must be carried out
by disconnecting it from the mains. If, after making the checks stated here, the
machine does not work, call the technical service.
Correction
Disassemble and clean the
faucet according Fig. 11A.
Check that the appliance's
ventilation grilles are not
blocked.
Contact your technical service.
Turn off the machine and turn it
back on again.
Fit the faucet in the manner
indicated in Fig. 11A
Contact your technical service.
Put the block in horizontal
position by pressing the faucet
downwards.
Activate the PulpOut in
continuous or intermittent
mode
Notify Technical Service

Screen Messages

Display Message
Cause
Excess current
The maximum electrical
consumption level has been
exceeded for at least one
second.
No oranges
The motor remains on for
two minutes detecting any
squeezing.
Memory initiated
A memory error has been
detected.
Calibration
An incorrect calibration value
has been detected.
Out of service
The counter has reached zero.
Eeprom
Error detected in EEPROM
memory.
Out of range
The input power voltage is
less than 80V or greater than
260V.
Keyboard error (error 1)
No communication with the
keyboard (Internal fault).
Juice tray picture flashing
Check the juice tray and front
cover are placed correctly.
Waste limit
Waste bucket full according to
the oranges specified.
*The message: "Keyboard error" may not appear on the display as there is no communication between the
CPU and the keyboard panel
EN
Correction
Turn off at mains and turn
back on again.
Put oranges back in feeder
again without and press ON.
Contact your technical service.
Calibrate.
Modify the discounter value as
indicated in page 21 or move
on to counter function entering
PARTIAL COUNTER and
pressing ON.
Contact your technical service.
Contact your technical service.
Contact your technical service.
Place the tray and cover in its
correct position as Fig. 4. If the
picture does not disappear,
contact your technical service.
Empty the waste bucket and
clean the machine.
41

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Versatile

Table des Matières