Stiebel Eltron BGC Mode D'emploi page 14

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 18
INSTALLATION
MOUNTING
BGC | BGC/45
1
≤ 65
BGC 2 | BGC 2/60
1
≤ 100
1 Extension (BGC/45 | BGC 2/60)
f If you install the appliance in a cylinder with thermal insula-
f
tion, use a threaded immersion heater with extension. You
can also use the extension to reduce the immersion depth
(see chapter "Specification / Data table"). The maximum
clearance between the threaded immersion heater and cylin-
der (see diagram) must not be exceeded.
14
| BGC
Connecting the power supply
WARNUNG Electrocution
Carry out all electrical connection and installation work
in accordance with relevant regulations.
WARNUNG Electrocution
Make the power supply only as a permanent connection.
The appliance must be able to be separated from the
mains power supply by an isolator that disconnects all
poles with at least 3 mm contact separation.
Geräte- und Umweltschäden
!
Observe the type plate. The specified voltage must match
the mains voltage.
Hinweis
Ensure that the appliance is earthed.
f Pull off the temperature selector.
f
f Undo the screws.
f
f Remove the cap.
f
f Prepare the power cable, ensuring that the earth conductor
f
is longer than the other conductors.
f Feed the power cable through the cable entry into the control
f
panel.
f Connect the required load in accordance with the connection
f
examples (see chapter "Specification / Wiring diagrams and
connections").
f Tick the selected connected load and voltage on the type
f
plate. Please use a ballpoint pen to do this.
f Affix the relevant wiring diagram label if required over the
f
wiring diagram in the cap.
Completing the installation process
f Replace the cap and secure it with screws.
f
f Replace the temperature selector.
f
100
200
WWW.STIEBEL-ELTRON.COM

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Bgc/45Bgc 2Bgc 2/60

Table des Matières