Rosemount Inc.
F
Figure B-28. Arborescence de menu du pocket de communication HART pour le
transmetteur de débit massique modèle 3095 MV
1 PROCESS
2 DIAGNOSTICS
1 O
-
FF
LINE
2 O
-
N
LINE
3 F
REQUENCY
D
EVICE
4 U
TILITY
3 BASIC SETUP
1 D
S
EVICE
ETUP
2 PV
3 PV AO
4 PV LRV
5 PV URV
Menu
Online
4 DETAILED
5 Review
1 Absolute AP
2 AP% R
ANGE
3 A01
VARIABLES
4 V
F
D
IEW
IELD
EV
5 V
O
IEW
UTPUT
1 T
/S
EST
TATUS
AND SERVICE
2 C
ALIBRATION
1 Tag
2 X
V
E
MTR
AR
NG
3 Range Values
4 D
I
EVICE
NFORMATION
5 C
ONSTRUCTION
M
ATERIALS
1 O
UTPUT
C
ONDITIONING
SETUP
2 S
IGNAL
C
ONDITIONING
3 LCD
4 T
OTALIZER
5 S
U
PECIAL
NITS
6 DP L
F
OW
LOW
C
UTOFF
1 Differential Pressure
2 Absolute Pressure
3 Process Temperature
4 Gage Pressure
1 Identify Primary Variable
V
ARS
5 Flow Rate
2 Primary Value
6 Flow Total
3 Primary Range
V
ARS
4 A01
1
V
P
V
.
IEW
RIMARY
AR
5 Change Prim. Var. Assign.
A
1
NALOG
1 Identify Secondary Var.
2 Secondary Value
3 Change Sec. Var. Assign.
2 V
S
V
.
IEW
ECOND
AR
1 Identify Tertiary Var.
2 Tertiary Value
3 V
T
V
.
3 Change Tert. Var. Assign.
IEW
ERTIARY
AR
1 Identify Fourth Variable
4 V
F
V
.
IEW
OURTH
AR
2 Fourth Value
3 Change 4th Var. Assign.
5 O
V
U
UTPUT
AR
NITS
1 Primary Var. Units
2 Secondary Var. Units
3 Tertiary Var. Units
1 Loop Test
2 View Status
4 Fourth Var. Units
3 Reset
1 DP Sensor Trim
2 AP Sensor Trim
1 S
T
ENSOR
RIM
3 GP Sensor Trim
4 Temp Sensor Trim
2 A
T
NALOG
RIM
1 D/A Trim
U
NITS
2 Scaled D/A Trim
1 DP Unit
3 Factory Trim
2 AP Unit
3 Process Temp
Unit
4 GP Unit
5 Flow Unit
1 Tag
2 Descriptor
3 Message
1 Universal Rev
4 Date
2 Fld Dev Rev
5 Final Assbly No.
3 Software Rev
6 Manufacturer
4 Hardware Rev
7 Model
5 Snsr Mod sw Rev
8 Write Protect
6 Snsr Mod hw Rev
9 R
EVISIONS
1 AO Alarm Type
1 A
O
NALOG
UTPUT
2 Loop Test
3 A
1 Poll Address
2 HART O
UTPUT
2 No Request Pream
3 No Response Pream
4 B
1 C
ALIBRATION
2 RTD Config
1 S
3 Atm Press Config
4 DP Damping
2 A
1 DP Damping
5 X
V
D
MTR
AR
AMPING
2 AP Damping
3 Temp Damping
4 GP Damping
1 DP Units
6 X
V
E
U
MTR
AR
NG
NITS
2 AP Units
3 Temp Units
4 GP Units
1 Display Period
5 Flow Units
2 Local Display
6 Flow Total Unit
1 Mode
2 Total
1 Base Unit
2 Scaling Factor
1 F
LOW
3 Unit String
1 Base Unit
2 T
OTAL
2 Scaling Factor
3 Unit String
B-2
1 DP Sensor Range
2 SP Sensor Range
3 SP Type
4 Isolator Material
5 Fill Fluid
6 Flange Material
7 Flange Type
8 Drain Vent Matl
9 O-Ring Material
10 RS Type
11 RS Fill Fluid
12 RS Isolator Matl
13 No of Rmt Seals
1 D/A Trim
2 Scaled D/A Trim
T
NALOG
RIM
3 Factory Trim
1 Burst Option
2 Burst Mode
3 Xmtr Var Slot Assn
M
O
URST
ODE
PER
1 DP Snsr Trim
T
ENSOR
RIM
2 AP Snsr Trim
3 GP Snsr Trim
4 Temp Snsr Trim
1 D/A Trim
T
NALOG
RIM
2 Scaled D/A Trim
3 Factory Trim