Venturi Adjustment; Flame Characteristics - Napoleon GD82NT-TE Instructions D'installation Et D'opération

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

10.3 VENTURI ADJUSTMENT

This appliance has an air shutter that has been factory set open according
to the chart below:
Regardless of venturi orientation, closing the air shutter will cause a more
yellow flame, but can lead to carboning. Opening the air shutter will cause a
more blue flame, but can cause flame lifting from the burner ports. The
flame may not appear yellow immediately; allow 15 to 30 minutes for the
final flame colour to be established.
AIR SHUTTER ADJUSTMENT MUST ONLY BE DONE BY A QUALIFIED
INSTALLER!

10.4 FLAME CHARACTERISTICS

It's important to periodically perform a visual check of the pilot and burner fl ames. Compare them to the
illustration provided. If any fl ames appear abnormal call a service person.
VENTURI
BURNER
ORIFICE
49.1
AIR SHUTTER
LP
NG
PILOT
ELECTRODE
BURNER
3/8" - 1/2"
(9.5mm - 12.7mm)
FLAME
SENSOR
FLAME MUST ENVELOP
UPPER 3/8" (9.5mm) TO 1/2"
(12.7mm) OF FLAME SENSOR
54.1B
43
EN
AIR
SHUTTER
OPENING
OPENINGS
1/2"
3/16"
W415-1410 / 11.20.14