EN
3
• Use a pencil to mark the intended location of the frame (distance from the wall: 100 mm)
and the angle bracket (not supplied). Provide at least 3 anchoring points at the feet, 2 of which must
be on the wall side.
• Remove the support frame and drill. You must choose the fasteners according to your wall (use
8 x 120 mm lag bolts; these parts are not supplied). Attach the angle bracket.
• Use the nuts to adjust the dimension between the wall and the edge of the frame; the distance
must be 100 mm.
• Check the alignment between the wall and the frame, the frame must be parallel to the wall.
• Attach the support frame.
7.4 Water supply
20
4
ATTENTION
• The water supply must be connected to a 14/16 copper
pipe with a 20/27 male threaded connection (not supplied).
The water supply is in the upper part of the frame.
• It is essential to install an accessible 1/4 turn shut-off valve
on the water inlet.
Note: The copper pipe must be held by a clamp to prevent
any movement when connecting the device.