Testing Of The Appliance; Adjustments; Instructions And Warnings For Adjustments - Angelo Po 1G1FA0G Manuel D'utilisation

Cuisinière feux vifs + four
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

TESTING OF THE APPLIANCE

Important
Before it is put into service, the system
must be tested to check the operating con-
ditions of every single component and
identify any malfunctions. In this stage, it is
important to check that all health and safety
requirements have been complied with in
full.
To test the system, make the following checks.
1 - Turn on the gas supply tap and check that the
connections are right.
2 - Check that the mains gas is the same as that
used for commissioning of the appliance, and
carry out the conversion procedure if necessary
(see page 18).

INSTRUCTIONS AND WARNINGS FOR ADJUSTMENTS

Important
Before making any type of adjustment, acti-
vate all the safety devices provided and de-
cide whether staff at work and those in the
vicinity should be informed. In particular,
turn off the gas supply tap and prevent ac-
cess to all devices which might cause un-
expected health and safety hazards if
turned on.
ADJUSTING GAS CONTROL VALVE MINIMUM SETTING (TOP
BURNERS)
Important
This adjustment is only required if the type
of gas to be connected is different from that
used for testing after the conversion proce-
dure has been carried out (see page 18). Be-
3 - Check that the top and oven burners are light-
4 - Check the gas pressure and flow-rate at mini-
5 - Check that the safety thermocouple is working
6 - Check that there are no gas leaks.
7 - Check that the nameplates specify the correct
After testing, if necessary instruct the user in all the
skills necessary for putting the appliance into oper-
ation in conditions of safety, in accordance with le-
gal requirements.

ADJUSTMENTS

Adjustments must be carried out by autho-
rised, qualifi ed staff , in accordance with
the relevant legal requirements.
fore making this adjustment, check that the
gas supply pressure is the same as the rat-
ed pressure for the type of gas in use (see
table at back of manual).
- 19 -
ing correctly and their combustion.
mum and maximum settings and adjust if nec-
essary (see page 13).
correctly.
gas for the country of use.
Important
8
IT
GB
DE
FR
ES
English

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

2g1fa0g2g1fadg1g1fabg2g1fabg

Table des Matières