After-Sales Service - Dimplex CFH60 Manuel D'instructions

Masquer les pouces Voir aussi pour CFH60:
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 10
Modular Linking
A number of fan heaters can be connected together in a 'daisy chain'
fashion. A total of ten units can be controlled from a single electronic
control panel. The required connections can be made in a daisy chain
fashion as shown in Fig. 9. (References shown below).
ECP - Electronic Control Panel
MU
- Master Unit
SU
- Slave Unit
MLC - Modular Linking Cable
CPC - Control Panel Cable
To make these connections remove one of the small knock-outs and feed
an appropriate LAN cable (not supplied) to the BUS OUT control socket
('D' in Fig. 9) of the Master Unit. Fix this cable in the back panel using
suitable cable gland (not supplied). Continue this process for all linked
heaters. Replace the control housing of each heater and power up all
units. Ensure that all control settings function correctly.
Thermal Safety Cut-out
The power supply to the heating elements will be interrupted if one or a
combination of the following abnormal events occurs:
1.
Air inlet or outlet grilles are obstructed.
2.
Internal ventilation is impaired due to build up of dust and fluff.
3.
Blower unit stalls.
Note: Before re-setting the cut-out, the reason for activation must be
determined and corrective action taken.
To reset the thermal safety cut-out, access reset button as shown in Fig.
6 and push in direction of arrow.
Recycling
For electrical products sold within the European
Community.
At the end of the electrical products useful life it should
not be disposed of with household waste. Please recycle
where facilities exist. Check with your Local Authority or
retailer for recycling advice in your country.
Cleaning
WARNING: DISCONNECT SUPPLY before carrying out maintenance.
External appearance can be maintained by wiping occasionally with a
damp cloth. For stain removal, a weak soap solution can be applied with
a cloth and the surface wiped dry. Care must be taken to avoid any moisture
ingress into the product.
After Sales Service
Should you require after sales service or should you need to purchase
any spares, please contact the retailer from whom the appliance was
purchased or contact the service number relevant to your country on the
warranty card.
Please do not return a faulty product to us in the first instance as this may
result in loss or damage and delay in providing you with a satisfactory
service.
Please retain your receipt as proof of purchase.
- 2 -
UK

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Cfh90Cfh120

Table des Matières