ASSEMBLING THE DOSATRON
ASSEMBLY SHOULD BE CARRIED OUT WITHOUT THE USE
OF TOOLS
the DOSatRON is delivered with :
- a mounting bracket,
- a suction tube with a strainer.
the bracket enables the DOSatRON
to be fixed to a wall.
Snap the DOSatRON into the bracket
by fitting the two lugs on one side of
the body (Fig. 1-A) into the corres-
ponding holes in the bracket (Fig.
1-B), and springing the bracket arms
apart until the other 2 lugs click into
place.
A
Fig. 1
©
DOSatRON INtERNatIONaL / 34
Remove the plastic caps (Fig. 1/2-C)
which block the inlet and outlet of your
DOSatRON before connecting to the
water supply.
the DOSatRON can be connected
to the water supply by means of
Ø 20 x 27 (3/4") bore flexible hose
and hose tail fittings with hose clips.
Make certain that water flows in the
same direction as the arrows on the
motor body.
B
RECOMMENDATIONS
Torque 20 N . m
%
5
thus 2kg . m
(Remember : 1 N . m = 0.1DaN.M)
C
EXTERNAL INJECTION (IE) MODELS
In order to use corrosive concentrates, the external injection model DOSatRON
is also delivered with an external injection hose (Fig. 2-D).
CaUtION screw in the components carefully !
C
©
©
DOSatRON INtERNatIONaL / 35
DOSatRON INtERNatIONaL / 35
D
Fig. 2