8.
Wheel balancing
WARNING – Incorrectly balanced wheels
Risk of injury due to change in handling cha-
racteristics of vehicle.
WBE 4220 must be positioned on a flat
surface and must be firmly bolted to the
floor.
Specified flange must be mounted on
clean and grease-free shaft.
Use the specified accessories (cone, spa-
cer rings).
Rim must contact flange accurately, remo-
ve any dirt.
Perform a check measurement after apply-
ing balancing weights.
1. Switch on the SBMV955 at the on/off switch.
« The "Start page" is opened.
2. Open the "main page" with <F1>.
8.1
Selection of vehicle type and balan-
cing program
i
Static balancing is recommended for wheels with
a width of less than 3.5": In this case only the rim
diameter value is entered. The values for distance
and width of the rim can be set arbitrarily in inches
or mm.
1. Open the "Program selection" menu with <F2>.
2. Check the currently selected type of vehicle
(passenger car or motorcycle) in the status bar. Alter
with <F3> if necessary and confirm with <OK>.
3. Check the currently selected balancing program in the
status bar. Alter with <F2> if necessary and confirm
with <OK>.
|
|
656 407
2010-11-22
Static balancing on plane 3
Static balancing on plane 2
Static balancing on plane 1
Pax2: Pax rim for concealed adhesive weights
Pax1: Pax rim with adhesive weights
Alu5: Adhesive weights on inside /
clip-on weights on outside
Alu4: Clip-on weights on inside /
adhesive weights on outside
Alu3: Clip-on weights on inside /
concealed adhesive weights on outside
Alu2: Concealed adhesive weights
Alu1: Standard program for adhesive weights
Standard program for clip-on weights
8.2
Entering rim data
i
If electronic recording is not possible, the wheel
data can also be entered manually (main page <F1>
or in program selection <F5>).
i
The electronic gauge arm is not required for the
balancing programs Alu2, Alu3 and Pax2 (Easyfix®).
Both measurement locations are recorded with the
vernier caliper.
1. Apply the electronic vernier caliper for rim distance
and rim diameter to the rim.