INSTRUCTION FOR USE
NOTE
For correct scrubbing/drying of floors at the sides of the walls. It is suggested to go near the walls
with the right side of the machine (A and B, Figure 15) as shown in the figure.
CAUTION!
To avoid any damage to the floor surface, turn off the brushes/pad-holders when the machine stops in one
place.
TANK EMPTYING
An automatic float shut-off system (A, Figure 16) blocks the vacuum system when the recovery water tank (B) is full. The vacuum
system deactivation is signaled by a sudden increase in the vacuum system motor noise frequency, also the floor has not dried.
CAUTION!
If the vacuum system turns off accidentally (for
example, when the float is activated because of a
sudden machine movement), to resume the oper-
ation: turn off the vacuum system by pressing the
switch (49, Figure 3), then open the cover (C, Fig-
ure 16) and check that the float inside the grid
(A) has gone down to the water level. Then close
the cover (C) and turn on the vacuum system by
pressing the switch (49, Figure 3).
When the recovery water tank (B, Figure 16) is full, empty it accord-
ing to the following procedure.
Figure 15
20
ENGLISH
C
B
A
Figure 16