2.4

minimum clearance to combustibles

WARNING
!
Do not install into any area having less than 7 feet (2.1m) (ceiling to appliance bottom, excluding hearth height).
BACK WALL
D
C
A
B
CONFIGURATION
K
Straight with single wall pipe
J
J
J
Straight with double wall pipe
Through the wall with single wall pipe
I
Through the wall with double wall pipe
Straight with single wall pipe
Straight with double wall pipe
Through the wall with single wall pipe
Through the wall with double wall pipe
CONFIGURATION
Corner (F)
Corner (F)
BACK WALL
BACK WALL
E
D
C
A
E
B
K
J
I
*
*
*
*
Top Heat
Shield
BACK WALL
BACK WALL
E
D
C
A
E
F
E
B
SIDE WALL
SIDE WALL
TO FLUE
(A)
(B)
K
J
J
16 1/4"
27 1/2"
(41.2cm)
(69.8cm)
I
16 1/4"
27 1/2"
(41.2cm)
(69.8cm)
*
SIDE WALL
SIDE WALL
TO FLUE
4"
14 1/4"
(10.1cm)
(36.1cm)
6"
16 1/4"
(15.2cm)
(41.3cm)
* The top heat shield (T.H.S) may be removed if desired
(Fig. 2-3); however, this will increase clearances to
combustibles. Please read the above table carefully.
Clearances can be reduced with shielding acceptable to
local authorities. Reduced installation must comply with
NFPA 211 or CAN/CSA-B365.
Fig. 2-3
installation planning
BACK WALL
E
F
F
E
F
BACK
BACK
WALL TO
WALL (C)
FLUE (D)
9 1/2"
11"
(24.1cm)
(27.9cm)
6 1/2"
7 1/2"
(16.5cm)
(19cm)
9 1/2"
11"
(24.1cm)
(27.9cm)
6 1/2"
7 1/2"
(16.5cm)
(19cm)
14 1/2"
16"
(36.8cm)
(40.6cm)
12 1/2"
13 1/2"
(31.7cm)
(34.2cm)
14 1/2"
16"
(36.8cm)
(40.6cm)
12 1/2"
13 1/2"
(31.7cm)
(34.2cm)
BACK
BACK
WALL TO
WALL
FLUE
4"
14 1/4"
(10.1cm)
(36.1cm)
6"
16 1/4"
(15.2cm)
(41.2cm)
W415-2837 / B / 06.22.21
EN
F
CEILING
(E)
84"
(213.3cm)
96"
(243.8cm)
CEILING
84"
(213.3cm)
96"
(243.8cm)