SOMFY Soliris io Notice page 26

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 1
EN
3] Unscrew the front panel of the mounting bracket (O) to remove
the housing and access the terminal blocks and the mode selector.
4] If necessary, loosen the screws fastening the mounting bracket
to the wall.
2.6.3. Unpairing Soliris io from an io receiver or motor
The procedure to be followed to unpair Soliris io from an io receiver or motor is identical to the pairing
procedure, see 2.5.1.
2.6.4. Replacing a broken or faulty Soliris io
1] Press the PROG button on the Somfy io local control point until
the motorised product performs an up-and-down movement (≈
2 s).
2] Press the PROG button (I) on the new Soliris  io sensor for
7 seconds :
The Wind LED (K) on the new Soliris io sensor is lit green after
2 seconds and remains lit for 5 seconds:
All the broken or faulty sensors are deleted from the memory of the io motor(s) or receiver(s).
3] Pair the new Soliris io sensor with the io motor(s) or receiver(s); see 2.5.1.
2.6.5. Returning Soliris io to its original configuration
1] Press the PROG button (I) on Soliris io for 7 seconds :
The Wind LED (K) is lit green after 2 s and remains lit for 7 s :
The original Soliris io settings have been restored and the io bi-directional control points have been
deleted.
2] To use Soliris io again, carry out a complete commissioning procedure; see 2.5.