1] Switch off the mains power supply.
2] Unscrew the front panel (N) of the mounting bracket to access
the terminal block.
Attention
Never remove the cover located under the anemometer.
3] Unscrew the left-hand metal tab (O).
4] Drill a hole in the left-hand sealant pad (P).
Attention
• Never remove the sealant pad.
• The hole drilled in the pad must not exceed the diameter of the
cable in order to maintain tightness.
5] Feed the cable (B) through the sealant pad.
6] Connect the power supply cable (B) to the sensor using the left-
hand terminal block marked "230V" (Q).
Attention
The cable must be stripped to 6 mm.
7] Screw in the metal tab (O): the cable must be fed under the tab.
Attention
The cable sheath must exceed the tab by at least 2 mm.
͉
͉
To add the wiring for a rain sensor (e.g. Ondeis), go to section 2.3.2.
8] Check the presence, good condition and the position of the seal
(R) before fitting the cover.
9] Screw the front panel (N) of the mounting bracket back on.
Attention
Tighten the screws completely to maintain the tightness of the
mounting bracket.
To complete the installation, go to section 2.4.
18
Copyright
©
2019-2020 SOMFY ACTIVITES SA, Société Anonyme. All rights reserved.
OFF
1]
2]
N
3]
O
4]
P
5]
B
6]
Q
7]
O
8]
R
9]
N
Soliris io
B
230V
≥2mm