Operation; Operating Modes - Sime ECOMAXI 160ErP Mode D'emploi

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Installation, use and maintenance manual
Maintenance
LED
Alarm LED
Degrees
Celsius LED
Degrees
Fahrenheit LED
On/Stand-by
LED
7.1.1.6
Warnings
Loc
The keypad is locked (see section 7.1.3.3).
dEFr
Defrosting is in progress. Other functions cannot
be activated.
Anti
The Anti-legionella function is in operation.
ObSt
The Overboost function is in operation.
ECO
The Economy function is in operation.
Auto
The Automatic function is in operation.
7.1.2

OPERATION

7.1.2.1

Operating modes

The appliance can operate in the following
modes:
AUTOMATIC mode
This mode uses mainly renewable energy from
the heat pump and can activate the auxiliary
electrical resistors. The resistors are activated
where the water temperature falls below a set
level, or where a temperature above 62°C is
required (parameter SP5);
ECONOMY mode
This mode uses solely renewable energy from
the heat pump without ever activating the
electrical resistors. This requires more time but
provides significant energy savings;
If is on: the air filter requires
maintenance (if present)
If it is on: check the list of
alarms
and
follow
procedure indicated in this
manual
If
it
is
on:
the
unit
measurement for temperature
is degrees Celsius
If
it
is
on:
the
unit
measurement for temperature
is degrees Fahrenheit.
If it is on: the device is in
stand-by mode.
If it is flashing: the appliance
has
been
switched
on/off
manually while in automatic
timed on/off mode.
Not used
OVERBOOST mode
This mode allows you to heat water quickly
using both the heat pump and the electrical
resistors. This
the
manually when the temperature of the water
inside the storage tank is below 40°C. At the
end of the heating process, the function is
of
disabled automatically and the product reset
to Automatic or Economy mode, depending
on the previous setting chosen by the user.
of
ANTI-LEGIONELLA mode
This mode is used as an anti-bacterial
treatment which works by increasing the
temperature of the water up to 70°C. This
mode is activated automatically every 30
days, regardless of the active operating mode;
DEFOSTING MODE
This mode is required for removing frost
deposits that form and block heat transmission.
This mode is automatically activated when
operating in low room temperatures.
The first time you turn on the appliance you
will see that it has been pre-set by the
manufacturer to ECO (Economy) mode,
with a water setpoint of 55°C. This is to
guarantee maximum energy savings, using
only renewable energy sources. Please
note that by using this mode, users can
make an average energy saving of 70% as
compared with a standard electric boiler.
MANUAL CODE: 6328407
function can
be
activated
Page 58 / 148

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

8115810

Table des Matières