A) A minimum clearance value determined by testing in accordance with Clause 5.20, or;
B) A reference to the following footnote:
"Clearance in accordance with local installation codes and the requirements of the gas supplier."
• A vent shall not terminate directly above a sidewalk or paved driveway that is located between
two single family dwellings and serves both dwellings.
• Permitted only if veranda, porch, deck, or balcony is fully open on a minimum of two sides beneath
the floor.
16
Clearance to outside corner
Clearance to inside corner
Clearance to each side of
center line extended above
meter /regulator assembly
Clearance to service
regulator vent outlet
Clearance to non-
mechanical air supply
inlet to building or the
combustion air inlet to any
other appliance
Clearance to a mechanical
air supply inlet
Clearance above paved
sidewalk or paved driveway
located on public property
Clearance under veranda,
porch, deck or balcony
Product Support: Eccotemp.com/help-desk
*
*
*
*
4 ft (1.2 m) below or to side
of opening; 1 ft (300 mm)
above opening
3 ft (91 cm) above if within
10 ft (3 m) horizontally
*
*
Shop Online: Eccotemp.com/products
3 ft (91 cm) within a height 15
ft above the meter/regulator
assembly
3 ft (91 cm)
6 in (15 cm) for appliances ≤
10,000 Btuh (3 kW), 12 in (30
cm) for appliances > 10,000
Btuh (3kW) and ≤ 100,000
Btuh (30 kW), 36 in (91 cm)
for appliances >
100,000 Btuh (30 kW)
6 ft (1.83 m)
7 ft (2.13 m)
12 in (30 cm)