Ibiza Light QUAD6-FX Manuel D'utilisation page 4

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 7
CAUTION
Do not allow contact between the common and the fixture's chassis ground. Grounding the common can cause
a ground loop, and your fixture may perform erratically. Test cables with an ohm meter to check correct polarity
and to make sure the pins are not grounded or shorted to the shield or each other.
SETTING UP A DMX SERIAL DATA LINK
1. Connect the (male) 3 pin connector side of the DMX cable to the output (female) 3 pin connector of the con-
troller.
2. Connect the end of the cable coming from the controller which will have a (female) 3 pin connector to the
input connector of the next fixture consisting of a (male) 3 pin connector.
3. Then, proceed to connect from the output as stated above to the input of the following fixture and so on.
MASTER/SLAVE FIXTURE LINKING
1. Connect the (male) 3 pin connector side of the DMX cable to the output (female) 3 pin connector of the first
fixture.
2. Connect the end of the cable coming from the first fixture which will have a (female) 3 pin connector to the
input connector of the next fixture consisting of a (male) 3 pin connector. Then, proceed to connect from the
output as stated above to the input of the following fixture and so on
Often, the set up for Master-Slave and Stand-alone operation requires that the first fixture in the chain be initial-
ized for this purpose via either settings in the control panel or DIP-switches. Secondarily, the fixtures that follow
may also require a slave setting. Please consult the '' Operating Instructions» section in this manual for complete
instructions for this type of setup and configuration.
NAVIGATION THROUGH THE CONTROL PANEL
Access control panel functions using the four panel buttons located directly underneath the LCD Display..
Button
Function
MENU
Used to access the menu or to return to a previous menu option
UP
Scrolls through menu options in ascending order
DOWN
Scrolls through menu options in descending order
ENTER
Used to select and store the current menu or option within a menu
To access the main menu press the MENU button. Press the UP or DOWN buttons until you reach function you
wish to change. When you reach the function you wish to change, press the ENTER button. When a function
is selected, use the UP or DOWN buttons to change the function settings. Once your changes are made, press
the ENTER button, and then press and hold the MENU button for at least three seconds to confirm and lock the
change into the system memory. To exit without making any adjustments, press the MENU BUTTON. The display
will lock after 30 secondes. Press the MENU button for 3 seconds to unlock.
MENU MAP
ADDR
A001---A512 (DMX ADDRESS)
CHND
11CH, 15CH (DMX CHANNEL OPTION)
SLND
MAST, SL 1, SL 2 ( MASTER, SLAVE OPTION)
SHND
Sh O - Sh15: Show mode
Auto
OFF/ON: Auto Mode
SOUN
ON /OFF (SOUND CONTROL)
SENS
Sound sensitivity control (0 close, 100 The most sensitive)
PINT
YES, NO (Pan positive direction or reverse direction)
TINI
YES , NO (Tilt 1 positive direction or reverse direction)
TIN2
YES , NO (Tilt 2 positive direction or reverse direction)
LED
ON, OFF (Background LIGHT ON/OFF)
DISP
YES, NO (Reverse Display)
TEST
Auto test
RSET
YES, NO Restore factory settings
4
Manual - QUAD6-LED
OPERATING INSTRUCTIONS
©Copyright LOTRONIC 2020
8.8.8.8.
MENU
UP
DOWN
ENTER

Publicité

Table des Matières
loading