Product duration
The duration and average economic life of the product. The value of duration is
strongly affected by the fatigue index of the manoeuvres performed by the
automation: i.e. the sum of all factors that contribute to wear of the product
(see Table 1).
To establish the probable duration of your automation, proceed as follows:
01. Calculate the fatigue index by adding the percentage values of the items
present in Table 1;
02. In Graph 2 of the value just found, trace a vertical line that crosses the
curve; from this point trace a horizontal line until the "manoeuvre cycles" line is
crossed. The value determined is the estimated duration of your product.
The estimation of duration is made on the basis of the design calculations and
the test results performed on prototypes. In fact, as it is an estimate, it does not
represent any guarantee regarding the effective duration of the product.
Length
≤ 2 m
of the panel
< 150 Kg
0 %
150 - 350 Kg
10 %
350 - 550 Kg
20 %
550 - 750 Kg
30 %
750 - 900 Kg
40 %
Environmental temperature exceeding 40°C or
below 0°C or humidity exceeding 80%
Blind panel
Installation in windy area
Declaration in accordance with the Directives: 2004/108/EC (EMC); 2006/42/EC (MD) appendix II, part B
Note - The contents of this declaration correspond to declarations in the official document deposited at the registered offices of Nice S.p.a. and in particular to the last revision
available before printing this manual. The text herein has been re-edited for editorial purposes.
A copy of the original declaration can be requested from Nice S.p.a. (TV) I
Number: 389/BM..
Manufacturer's Name:
Adress:
Person authorised to draw up
technical documentation:
Type:
Models:
Accessories:
The undersigned, Luigi Paro, in the role of Managing Director, declares under his sole responsibility, that the product specified above conforms to the pro-
visions of the following directives:
• DIRECTIVE 2004/108/EC OF THE EUROPEAN PARLIAMENT AND COUNCIL of 15 December 2004 regarding the approximation of member state legi-
slation related to electromagnetic compatibility, repealing directive 89/336/EEC, according to the following harmonized standards:
EN 61000-6-2:2005, EN 61000-6-3:2007
Directive 2006/42/EC THE EUROPEAN PARLIAMENT AND COUNCIL of 17 May 2006 regarding machinery and which amends directive 95/16/EC (recasting)
• It is hereby declared that the pertinent technical documentation has been compiled in compliance with appendix VII B of directive 2006/42/EC and that
the following essential requirements have been observed: 1.1- 1.1.2- 1.1.3- 1.2.1-1.2.6- 1.5.1-1.5.2- 1.5.5- 1.5.6- 1.5.7- 1.5.8- 1.5.10- 1.5.11
• The manufacturer undertakes to transmit to the national authorities, in response to a motivated request, all information regarding the "quasi-machine",
while maintaining full rights to the related intellectual property.
• Should the "quasi machine" be put into service in a European country with an official language other than that used in this declaration, the importer is obli-
ged to arrange for the relative translation to accompany this declaration.
• The "quasi-machine" must not be used until the final machine in which it is incorporated is in turn declared as compliant, if applicable, with the provisions
of directive 2006/42/EC.
The product also complies with the following standards:
EN 60335-1:2002 + A1:2004 + A11:2004 + A12:2006 + A2:2006 + A13:2008, EN 60335-2-103:2003
The product also complies, within the constraints of applicable parts, with the following standards:
EN 13241-1:2003, EN 12445:2002, EN 12453:2002, EN 12978:2003
Oderzo, 1 April 2011
6 – English
TABLE 1
2 - 3 m
3 - 4 m
4 - 5 m
Fatigue index
10 %
20 %
20 %
30 %
30 %
40 %
40 %
50 %
50 %
-
CE DECLARATION OF CONFORMITY
and declaration of incorporation of "quasi machinery"
Revision: 0
NICE s.p.a.
Via Pezza Alta 13, Z.I. Rustignè, 31046 Oderzo (TV) Italy
Mr. Oscar Marchetto
"Big Metro" electromechanical gearmotor
BM5024
250.000
200.000
150.000
100.000
50.000
30 %
40 %
Example of the duration calculation of an Big Metro gear motor (refer to
50 %
Table 1 and Graph 2):
-
- panel length: 3 m and panel weight: 500 Kg = fatigue index: 30%
-
- Installation in windy areas = fatigue index: 15%
- does not have other elements of fatigue
15 %
Total fatigue index = 45%
Estimated duration = 110.000 manoeuvre cycles
20 %
15 %
Language: EN
Luigi Paro (Managing Director)
GRAPH 2
fatigue index %