WAGNER W 867 E Mode D'emploi page 31

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

W 867 E
Turn the gun front part and gun rear part against each other.
ATTENTION: Never hold the gun handle under water or immerse it into liquids.
Clean the housing only with a moistened cloth.
3)
Unscrew the container. Empty any remaining coating material back into the material
tin.
4)
Preclean the container and feed tube with a brush. Clean the ventilating bore (Fig.11,
item C).
5)
Pour solvent or water into the container. Screw the container back on.
Use only solvents with a flashpoint over 21°C.
6)
Assemble the gun again (Fig. 6).
7)
Turn on the machine and spray the solvent or water into a container or a cloth.
8)
Repeat the above procedure until the solvent or water emerging from the nozzle is
clear.
9)
Turn off the machine and divide the spray gun.
10)
Screw of the container and empty it. Pull out the suction tub with container seal.
CAUTION! Never clean seals, diaphragm and nozzle or air holes of the
spray gun with metal objects.
The ventilation hose and diaphragm are only solvent-resistant to a limited
extent. Do not immerse in solvent, only wipe.
11)
Pull the ventilating hose (Fig.11 A, item 13) at the top from the gun body. Screw off
the valve cover (14). Remove the diaphragm (15). Clean all the parts carefully.
12)
Unscrew the union nut and remove the air cap and nozzle. Clean the air cap, nozzle
seal and nozzle with a brush and solvent or water (Fig. 11, item 5).
13)
Clean the outside of the spray gun and container with a cloth soaked in solvent or
water.
14)
Assemble the parts again (see "Assembly").
Assembly
The unit may only be operated with an integer diaphragm (Fig. 11A, item 15). Place the
diaphragm with the pin facing upwards on the bottom section of the valve. Also see
the marking on the gun body. Place on the valve cover and screw it closed. Place the
ventilating hose on the valve cover and on the nipple at the gun body.
Slide the nozzle seal (Fig. 11, item 4) with the groove (slot) facing forwards into the nozzle
(Fig. 11B). Put the nozzle onto the gun body and find the correct position by turning it.
Put the air cap onto the nozzle and tighten it using the union nut.
Place the container seal from below on the suction tube and slide it over the collar, while
turning the container seal slightly. Insert the suction tube with container seal in the gun
body.
Maintenance
WARNING!
Change the air filter if it is soiled. Unplug the power plug. Open the cover of the air filter
compartment (Fig. 12). Insert a new air filter into the compartment. Close the cover of
the air filter compartment.
Never operate the machine without the air filter; dirt could
be sucked in and interfere with the function of the machine.
Do not store any objects in the air filter compartment.
GB
25

Publicité

Table des Matières
loading

Table des Matières