1
User
The CP field bus node 13 is intended exclusively for use as
a slave on the PROFIBUS−DP. The maximum values speci
fied in the section Technical specifications" must be ob
served here.
Detailed information can be found in the manual
P.BE−CP−FB13−E.. .
Warning
S Switch off the power supply before connecting or
disconnecting plugs (otherwise this could lead to
functional damage).
S Use power supplies which guarantee reliable electri
cal isolation of the operating voltage as per IEC/DIN
EN 60204−1. Consider also the general requirements
for PELV circuits in accordance with IEC/DIN EN
60204−1.
S Connect an earth conductor of sufficient cross−sec
tional area to the terminal marked with the earth
symbol.
S Commission only a CP system which has been fitted
and wired completely.
Festo CP−FB13−E 0802e English
instructionsEnglish
13