4 Introductory information
About warnings and cautions
Caution statements can appear on the Welch Allyn blood pressure device, the packaging,
the shipping container, or in this Directions for use.
The Welch Allyn blood pressure device is safe for patients and clinicians when used in
accordance with the instructions and caution statements presented in this Directions for
use.
Before using the device, you must familiarize yourself with all cautions, with the steps to
power up the device, and with the sections of this Directions for use that pertain to your
use of the device. In addition to reviewing the general cautions presented in the next
section, you must also review the more specific cautions that appear throughout the
manual in conjunction with setup/startup, operation, and maintenance tasks.
•
Failure to understand and observe any warning statement in this manual could lead
to patient injury or illness.
•
Failure to understand and observe any caution statement in this manual could lead to
damage to the equipment or other property, or loss of patient data.
General warnings and cautions
Warning Patient injury risk. The device is not suitable for measuring the
blood pressure of neonatal infants or children. Ask your doctor before using
it with older children.
Warning Patient injury risk. The device is not suitable for use on pregnant
women, patients with implanted electrical devices, patients with pre-
eclampsia, premature ventricular beats, atrial fibrillation, peripheral arterial
disease, and patients undergoing intravascular therapy or arterio-venous
shunt or people who received a mastectomy. Consult your doctor prior to
using the unit if you suffer from any of these illnesses or conditions.
Warning Patient injury risk. Do not take any therapeutic measures on the
basis of a self measurement. Never alter the dose of a medicine prescribed
by a doctor. Consult your doctor if you have any question about your blood
pressure.
Warning Patient injury risk. Keep the unit out of reach of infants, children,
or pets, since inhalation or swallowing of small parts is dangerous or even
fatal.
Warning Patient injury risk. The device is not intended to be a self-
measurement station used in a public place or center.
Warning Patient injury risk. Do not burn batteries. Batteries may leak or
explode.
Warning Patient injury risk. If you experience discomfort during a
measurement, such as pain in the arm or other complaints, press the
Standby symbol immediately to release the air from the cuff. Loosen and
remove the cuff from your arm.
Welch Allyn Remote Monitoring Blood Pressure Device RPM-BP100
Annexes
Spécifications
Avertissement : Aucune modification de cet équipement n'est autorisée.
Élément
Alimentation : Mode alimenté par pile :
Alimentation : Mode alimenté par adaptateur CA :
Mode d'affichage
Mode de mesure
Plage de mesures
Précision
Conditions de fonctionnement normal
Condition de transport et de stockage
Périmètre de mesure du bras
Poids net
21
Caractéristiques
4 piles AA 6 V CC
Entrée : 100-240 V, 50-60 Hz, 400 mA ;
Sortie : 6 V, 1 A
LCD numérique V.A. 68 mm*90 mm
Mode de test oscillométrique
Pression du brassard détectée :
0 mmHg-300 mmHg (0 kPa-40 kPa)
Pression de la mesure :
SYS : 60-230 mmHg
DIA : 40-130 mmHg
Valeur du pouls : (40-199) battement/minute
Pression :
5 -40
entre ±0,4 kPa (3 mmHg)
Valeur du pouls : ±4 %
Température : 5
à 40
Humidité relative 85 % HR
Pression atmosphérique : 86 kPa à 106 kPa
Température : 20
à 60
Humidité relative : 10 % HR–93 % HR
Pression atmosphérique : 50 kPa à 106 kPa
Environ 22 cm~42 cm
Approx. 300 g (À l'exclusion des piles sèches)