3.12
Separate, untwist and unkink the three 80" motor leads.
Route the 80" black, blue and white motor leads
through the downrod (Figure 11).
3.13
Loosen the two setscrews in the motor coupling.
Place the 4.5" downrod into the motor coupling, aligning
the clevis pin holes in the downrod with the holes in the
motor coupling (Figure 12).
The clevis pin must go through the holes in the motor
coupling and the holes in the downrod.
Be sure to push the straight leg of the hairpin clip
through the hole near the end of the clevis pin until the
curved portion of the hairpin clip snaps around the
clevis pin.
The hairpin clip must be properly installed to prevent
the clevis pin from working loose.
Pull on the downrod to make sure the clevis pin is
properly installed.
It is critical that the clevis pin in the motor coupling is
properly installed. Failure to verify that the pin is
properly installed could result in the fan falling.
3. Ceiling Fan Assembly
WARNING
!
(Continued)
THREE 80" MOTOR
LEADS (UNTWISTED)
Figure 11
4.5"
DOWNROD
CLEVIS
PIN
MOTOR
COUPLING
Figure 12
Please contact 1-800-654-3545 for further assistance
9
4.5" DOWNROD
HAIRPIN
CLIP
CLEVIS
PIN
HAIRPIN
CLIP
LOOSEN
SETSCREWS (2)