Regardless of venturi orientation, closing the air
shutter will cause a more yellow fl ame, but can lead to
carbonization. Opening the air shutter will cause a more
blue fl ame, but can cause fl ame lifting from the burner
ports. The fl ame may not appear yellow immediately;
allow 15 to 30 minutes for the fi nal fl ame colour to be
established.
AIR SHUTTER ADJUSTMENT MUST ONLY BE
DONE BY A QUALIFIED INSTALLER!

9.13 pilot burner adjustment

Adjust the pilot screw to provide properly sized fl ame. Turn in a clockwise direction to reduce the gas fl ow.
Check Pressure Readings:
Inlet pressure can be checked by turning screw (A) counter-
clockwise 2 or 3 turns and then placing pressure gauge tubing
over the test point. Gauge should read as described on the chart
below. Check pressure with main burner operating on "HI".
Outlet pressure can be checked the same as above using screw
(B). Gauge should read as described on the chart below. Check
pressure with main burner operating on "HI".
After taking pressure readings, be sure to turn screws
clockwise fi rmly to reseal. Do not overtorque.
Leak test with a soap and water solution.
Prior to pilot adjustment, ensure that the pilot assembly has not been painted. If overspray or painting of
the pilot assembly has occurred remove the paint from the pilot assembly, or replace. Fine emery cloth or a
synthetic scrub pad (such as Scotch-Brite™) can be used to remove the paint from the pilot hood, electrode
and fl ame sensor.
Pressure
Natural Gas
(inches)
Inlet
(minimum 4.5")
Outlet
3.5"
9.14 fl ame characteristics
It's important to periodically perform a visual check of
the pilot and burner flames. Compare them to the
illustration provided. If any flames appear abnormal,
call a service person.
Natural Gas
(millibars)
*7"
17.4mb
(minimum 11.2mb)
8.7mb
Air Shutter
Opening
Lever
B
A
B
A
INSERT PILOT ASSEMBLY
Propane
(inches)
13"
(minimum 11")
(minimum 27.4mb)
10"
*Maximum inlet pressure not to exceed 13"
3/8" - 1/2"
(9.5mm - 12.7mm)
Flame must envelop
upper
3/8" to 1/2"
(12.7mm - 9.5mm) of
Flame sensor
fi nishing
Fig. 2
PILOT SCREW
PILOT SCREW
Propane
(millibars)
32.4mb
24.9mb
W415-1935 / C / 01.13.20
EN
45

Publicité

Chapitres

Table des Matières
loading

Ce manuel est également adapté pour:

Altitude x ax42nteAltitude x ax36pteAltitude x ax42pte

Table des Matières