venting installation
EN
4.3.4 restricting vents
WARNING
!
•
Turn off gas and electrical supply before servicing the appliance.
•
Appliance may be hot, do not service until appliance is cool.
•
For safe and proper operation of the appliance, follow the venting instruction exactly.
•
To avoid danger of suffocation, keep the packaging bag away from babies and children. Do not use in
cribs, beds, carriages or play pens. This bag is not a toy. Knot before throwing away.
Vertical installations may display a very active fl ame. If this appearance is not desirable, the exhaust outlet may be
restricted with a Wolf Steel approved restrictor kit.
A.
The exhaust outlet reducer is factory installed for all vent confi gurations.
B.
Depending on the amount of restriction desired, the restrictor plate (supplied) can be installed fl at for the
most restriction or bent up for varying degrees of restriction (see Figure 3 for restriction guide).
The restrictor
plate MUST
rest on this tab.
Exhaust outlet reducer
NATURAL GAS
28
W415-1935 / C / 01.13.20
2
Restrictor Plate
45°
20°
CLOSED
40 FT (20°)
40 FT (CLOSED)
30 FT (25°)
30 FT (10°)
20 FT (35°)
20 FT(20°)
10 FT (45°)
10 FT (45°)
8 FT (70°)
8 FT (70°)
PROPANE
NO RESTRICTION PLATE REQUIRED
1
Exhaust collar
#8x½ hex head
sheet metal screw
Fig. 1
70°
** FOR SEVERELY RESTRICTED VENT CONFIGURATIONS, THE PRE-INSTALLED
REDUCER MAY BE REMOVED.
Note: Adjust paddle based
on more "V" or "H"
NG / LP
Firebox top
1. Most restriction
2. Moderate restriction
Fig. 2
3. Least restriction
57" / 20' (80°)
MIN/MAX
Fig. 3