[Obstruc Detct]
With the leaf closed, open or after a total stop, the operator remains idle if the safety devices, like photocells or sensitive safety-edges)
detect and obstruction.
[Safety Test]
After every opening or closing command, the board will check whether the photocells are working properly
[Prefl ashing]
After an opening or closing command, the fl ashing light connected to 10-E, fl ashes before the maneuver starts.
To set the time, see [Preflash time] in the SET TIMES menu.
[Ram Jolt]
Before each opening and closing, the gate-leaf gives a fi nal thrust to assist the electric-lock release. To adjust the thrust time, select [Ram
jolt time] in the SET TIMES menu.
[Total Stop]
NC input - Leaf stop while excluding any automatic closing; to resume movement, use the control device. The safety device is inserted into
[1-2].
[CX input]
NC input – Can associate: C1 = reopening during closing by photocells, C2 = reclosing during opening by photocells, C3 = partial stop, C4
= obstruction wait, C7 = reopening during closing by sensitive safety-edges, C8 = reclosing during opening by sensitive safety-edges.
[CY input]
NC input – Can associate: C1 = reopening during closing by photocells, C2 = reclosing during opening by photocells, C3 = partial stop, C4
= obstruction wait, C7 = reopening during closing by sensitive safety-edges, C8 = reclosing during opening by sensitive safety-edges.
[CZ input]
NC input – Can associate: C1 = reopening during closing by photocells, C2 = reclosing during opening by photocells, C3 = partial stop, C4
= obstruction wait, C7 = reopening during closing by sensitive safety-edges, C8 = reclosing during opening by sensitive safety-edges.
[Closing thrust]
At each closing endstop, the operator thrusts the fi nal closing of the leaf for a a few seconds.
[Lock]
Set the electric lock to lock the leaves, by choosing among one of the available choices.
[Lock Type]
Setting the type of electric lock:
- impulse electric lock - it activates for a few seconds when the gate is either open or closed. The activation time is adjusted by the[Lock
time] function
- continuous electric lock - it activates during the entire opening or closing maneuver.
[Confi g]
Configuring the opening and closing slow-downs
[Slow Down]*
➡ opening and closing slow-downs.
[Lsop-Clos. Slw]*
➡ opening endstop and closing slow-down.
[ENCODER]
➡ slow-down management, obstruction detection and sensitivity.
[Time Lmt Swtch]
➡ timed endstop.
[End Stop]
➡ opening and closing endstop.
slowdowns configurable with the [Slow down time] in the [Set Travel]
*
[End Stop]
Configuring the endstops as normally opened or closed contacts.
This function only appears if option is selected between [End Stop], [Lsop-Clos. Slw] or [Slow Down] from the [Confi g] function.
[2-7 command]
Configuration contact 2-7 in step-step (open-close) or sequential (open-stop-close-stop).
[Light E]
Configuring the light connected to 10-E:
- cycle: freely positionable outdoor light for increasing lighting in the driveway/parking area. It stays lit from the moment that the gate leaf
starts opening until it is completely closed (including the automatic closing time). In case the automatic closing is off, it stays on only during
the gate-leaves' movement.
- flashing: to alert when the moving leaf is either closing or opening.
[B1-B2 output]
Configuring contact B1-B2 in Monostable or Bistable mode (switch).
[Disabled] / [Enabled]
[Disabled] / [CX] / [CY] / [CZ] / [CX+CY] / [CX+CZ] / [CY+CZ] / [CX+CY+CZ]
[Disabled] / [Enabled]
[Disabled] / [Closing] / [Opening] / [Open-Close]
[Enabled] / [Disabled]
[Disabled] / [C1] / [C2] / [C3] / [C4] / [C7] / [C8]
[Disabled] / [C1] / [C2] / [C3] / [C4] / [C7] / [C8]
[Disabled] / [C1] / [C2] / [C3] / [C4] / [C7] / [C8]
[Disabled] / [Enabled]
[Disabled] / [Closing] / [Opening] / [Open-Close]
[Pulsed] / [Continuous]
[Slow Down] / [Op LS-Cl Sl Dn] / [ENCODER] / [Time Lmt Swtch] / [End Stop]
[N.C] / [N.O]
[Open-Close] / [Opn Stp Clse]
[Cycle] / [Flashing light]
[Monostable] / [Bistable]
.