E
c) If the red LED (7) flashes 3 times and simultaneously an audible alarm (3 signals) is
sounded, see Chapter 2.6.
Severe malfunction! If this error repeats, send in the device for repair. Do not open the
device or remove any seals. If this malfunction occurs only once, repeat the operation.
6.
Specifications
Protection class
Operating pressure:
Hydraulic oil:
Amount of oil:
Usable oil capacity:
Permissible ambient temperature:
Control voltage:
Drive motor:
Weight of the pump:
Battery voltage:
Battery capacity:
Battery charge time:
Sound pressure level:
Vibrations:
156
IP 43
700 bar (reduced to about 150 bar by AHPLS130JRG)
Rivolta S.B.H. 11
about 760 ml
about 740 ml
-12 °C to +40 °C
18 V DC
DC permanent field motor
approx. 4.9 kg
18 V
3 Ah (RAL2 / BL1830)
22 min. (RAL2 / BL1830)
<70 dB (A) at 1m distance
<2.5 m/s2 (weighted effective value of
acceleration)