ENG
Installation and user manual
1.2
TECHNICAL SPECIFICATIONS
Heating output – in accordance with EN255-3,
air temperature 20 °C, heating water from 15 °C to 45 °C.
Output
Total heating output (including electric booster heater)
COP
Standby energy consumption
Heating output – in accordance with 16147, XL cycle,
air temperature 15 °C, heating water from 10 °C to 54 °C.
COP
Heating time (HP only)
Standby energy consumption
Heating output – in accordance with 16147, XL cycle,
air temperature 7 °C, heating water from 10 °C to 54 °C.
COP
Heating time (HP only)
Standby energy consumption
General specifications
Description
Motor type Fan
Adjustment range sp1/sp2 (without pipe work)
Control ventilator
IP-class
Refrigerant/mass
Operating temperature
Maximum pressure compressor
Reservoir capacity
Maximum pressure vessel
Sound level (distance 1 meter-380m3/h)
Power supply
Max. power consumption
Nominal current (HP-only / HP + immersion heater)
Start-up current
Fuse rating
Electrical immersion heater
Plug type
Labels and markings
4
Unit
VHW 260
kW
1,7
kW
3,7
-
4,3
kW/day
0,74
Unit
VHW 260
-
3,2
-
8h48
kW/day
1,08
Unit
VHW 260
-
2,79
-
10h38
kW/day
0,97
Unit
VHW 260
-
Air/water heat pump
for DHW use
-
DC
m3/h
380/490
Adjustable by HMI
-
(2 speed)
-
21
-/gram
R134a/400
°C
-10 ... +35
Bar
27
Liter
250
Bar
10
dB(A)
50
V/Hz
230 /50
Watt
2600
A
2,6/11,3
A
13,5 max.
A
16
kW
2
-
Type E
-
CE/LCIE/WEEE/NF/
RoHS/REACH/ACS