Maintenance

Changing the Oil and Oil Filter

A
B
C
An Oil System Drain Pump Kit (P/N 0K3717) has been
shipped with this unit. Refer to the instructions included
with that kit for assembly and use of the Oil System Drain
Pump. If the Oil System Drain Pump has become lost, or
is unavailable, use a suitable suction pump to perform
the following oil change procedure.

EcoGen Oil System Drain Pump Kit Parts List

(Kit Part No. 0K3717)
A
¾ in. Spring Clamp**
B
½ in. Rubber Hose**
C
½ in. Barb Hose Fitting with ¾ in. Hose Thread**
D
Drill Pump
E
¼ in. Barb Hose Fitting w/¾ in. Hose Thread*
F
½ in. Spring Clamp*
G
¼ in. Rubber Hose*
* Parts 1, 2, and 6 come assembled from the supplier.
** Parts 3, 4, and 7 come assembled from the supplier.
24
B
Figure 4-3. Exploded View – EcoGen Oil System Drain Pump Kit
A
C
D

EcoGen Oil System Drain Pump Assembly

1. See
Figure
onto the inlet side of the Drill Pump. Twist the fitting
clockwise until it is snug. Do not over-tighten.
Figure 4-4. Pump Assembly Step 1
2. See
Figure
onto the outlet side of the Drill Pump. Twist the
fitting clockwise until it is snug. Do not over-tighten.
Figure 4-5. Pump Assembly Step 2
Owner's Manual for 60 Hz EcoGen™ Generator
E
F
G
4-4. Install the ¼ in. Hose Assembly
4-5. Install the ½ in. Hose Assembly
E
F G
001385
001386
001425