Technical data
HxWxL [mm]
Weight [kg]
Inlet [mm]
Hose length (Ø 50 mm) [m]
Collecting container [l]
3
Max. flow [m
/h]
Negative pressure, max. [kPa]
Power [W]
Fine filter, polyester, area [m
Efficiency, fine filter, EN 60335-2-69, Class M [%]
Filter area, HEPA filter [m
Efficiency, fine filter, EN 60335-2-69, Class H [%]
Filter classification, EN 1822-1
Sound level [dB(A)]
*/ Sound pressure level at 1.6 m height and 1 m distance according to DIN EN ISO 3744 in free field measurement at maximum
air flow.
Operation
Connection
Connect the machine to an electrical outlet with a voltage as per the machine's rating plate specifications. If using an extension
cord, it must be water-resistant.
Filter cleaning
1.
Keep the machine switched on and close the throttle at the cyclone inlet. Reset the filter cleaner button.
2.
Wait for 5-10 pulses.
3.
Open the throttle at the cyclone inlet and reset the filter cleaner button.
4.
Check that the pressure gauge indicates green or that the filter indication lamp is off. If not, repeat the procedure. If the
gauge indicates red or the light is on even after repetition, the fine filter needs to be replaced. If it, despite the filter change,
still indicates red, the vacuum valve must be checked.
16
2
]
2
]
Tromb Twin, Art.nr. 99039-A
DC Tromb Twin c
DC Tromb Twin L
1360 x 600 x 1280
1360 x 600 x 1280
76
80
Ø 76
Ø 76
5
5
20
longopac
365
365
20
20
3000
3000
2,5
2,5
99,9
99,9
2,2
2,2
99,995
99,995
HEPA H13
HEPA H13
70
70