Programmation
5.3.6 5-** E/S Digitale
Par.
Description du paramètre
No. #
5-0* Mode E/S digitales
5-00
Mode E/S digital
5-01
Mode born.27
5-02
Mode born.29
5-1* Entrées digitales
5-10
E.digit.born.18
5-11
E.digit.born.19
5-12
E.digit.born.27
5-13
E.digit.born.29
5-14
E.digit.born.32
5-15
E.digit.born.33
5-16
E.digit.born. X30/2
5-17
E.digit.born. X30/3
5-18
E.digit.born. X30/4
5-19
Arrêt de sécurité borne 37
5-20
E.digit.born. X46/1
5-21
E.digit.born. X46/3
5-22
E.digit.born. X46/5
5-23
E.digit.born. X46/7
5-24
E.digit.born. X46/9
5-25
E.digit.born. X46/11
5-26
E.digit.born. X46/13
5-3* Sorties digitales
5-30
S.digit.born.27
5-31
S.digit.born.29
5-32
S.digit.born. X30/6
5-33
S.digit.born. X30/7
5-4* Relais
5-40
Fonction relais
5-41
Relais, retard ON
5-42
Relais , retard OFF
5-5* Entrée impulsions
5-50
F.bas born.29
5-51
F.haute born.29
5-52
Val.ret./Réf.bas.born.29
5-53
Val.ret./Réf.haut.born.29
5-54
Tps filtre pulses/29
5-55
F.bas born.33
5-56
F.haute born.33
5-57
Val.ret./Réf.bas.born.33
5-58
Val.ret./Réf.haut.born.33
5-59
Tps filtre pulses/33
Manuel d'utilisation du VLT
Valeur par défaut (SR =
Dépend de la taille)
[0] PNP
[0] Entrée
[0] Entrée
null
null
null
null
null
null
null
null
null
[1] Arrêt sécurité alarme
[0] Inactif
[0] Inactif
[0] Inactif
[0] Inactif
[0] Inactif
[0] Inactif
[0] Inactif
null
null
null
null
null
0.01 s
0.01 s
100 Hz
100 Hz
0.000 ReferenceFeedbackUnit
ExpressionLimit
100 ms
100 Hz
100 Hz
0.000 ReferenceFeedbackUnit
ExpressionLimit
100 ms
®
MG.04.F1.04 - VLT
est une marque déposée Danfoss
®
Decentral Drive FCD 302
4 set-ups
Changement
pendant le
fonction-
nement
All set-ups
FALSE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
1 set-up
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
FALSE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
FALSE
Indice de
Type
conversion
-
Uint8
-
Uint8
-
Uint8
5
-
Uint8
-
Uint8
-
Uint8
-
Uint8
-
Uint8
-
Uint8
-
Uint8
-
Uint8
-
Uint8
-
Uint8
-
Uint8
-
Uint8
-
Uint8
-
Uint8
-
Uint8
-
Uint8
-
Uint8
-
Uint8
-
Uint8
-
Uint8
-
Uint8
-
Uint8
-2
Uint16
-2
Uint16
0
Uint32
0
Uint32
-3
Int32
-3
Int32
-3
Uint16
0
Uint32
0
Uint32
-3
Int32
-3
Int32
-3
Uint16
47
5