Maintenance; Replacing Batteries; Troubleshooting; Disposal - Honeywell VE300S Notice De Montage

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 11
Kartusche/Cartridge
Ohne / none
rinsing mode without cartridge
P300-LES
Setting of installed cartridge P300-LES
P300-LESxL
Setting of installed cartridge P300-LESxL*
P300-S
Setting of installed cartridge P300-S
P300-L
Setting of installed cartridge P300-L
* Available from March 2017
During rinsing mode without cartridge (none), connect
rinsing/blindplug, art. no. BS300-1/2A.
Other functions of the control keys
• Press and hold ON/INFO and Hardness control keys at the
same time for 3 s
- Information about total litres is reset to 0
• Press and hold Wasserhärte/Hardness and Kartusche/
Cartridge control keys at the same time for 3 s
- Information about cartridge changes is confirmed
• Press and hold ON/INFO and Kartusche/Cartridge control
keys at the same time for 3 s
- Valve ON/OFF

10. Maintenance

Maintenance, service and repair work may be carried
out only by authorised technicians.
We recommend taking out a servicing contract with an
installation firm
In accordance with DIN EN 1717 a regular maintenance must
be taken.
Frequency: every 1-3 years (depending on local opera-
ting conditions)
To be carried out by an installation company

10.1.Replacing batteries

The batteries have a service life of around 5 years
1. Take electronics module out of refilling unit
2. Replace batteries (alkaline AA 1.5V)
3. Reattach electronics module

12. Troubleshooting

Problem
Water is not of the desired hardness Hardness incorrectly set
Honeywell GmbH
GB
Cause
Cartridge capacity all used up
Dirt particles have entered the mixing openings Rinse cartridge
9
10.2.Replacing softening or demineralisation cart-
ridge
When the fill volume of the heating system exceeds the stated
capacity, the cartridge must be replaced.
Service LED
Flashing yellow cartridge capacity below 10 %
flashing red +
Cartridge capacity all used up
tone
Cartridge in use for more than 5
years
For softening:
For safety reasons, the softening cartridge must be
replaced 12 months after it is first used at the latest
For complete demineralisation:
For safety reasons, the complete demineralisation cart-
ridge must be replaced 12 months after it is first used at
the latest
1. Open bleeder valve and relieve pressure in system
• Place bucket under system
2. Unscrew cartridge from refilling unit
3. Screw in new cartridge until finger-tight
4. Press Wasserhärte/Hardness and Kartusche/Cartridge
control keys at the same time for 3 s
• Information about cartridge changes is confirmed
If the new cartridge differs from the old one, e.g. diffe-
rent sizes (L/XL), the new cartridge must be selected
and confirmed by selecting it with the Kartusche/Cart-
ridge button.

11. Disposal

• Dezincification-resistant brass housing
• Mechanical components of the heater water treatment unit
made of high-quality plastic
• EPDM seals
• Polypropylene cartridge
• 2 AA Alkaline batteries
• EPP insulation shells
Observe the local requirements regarding correct waste
recycling/disposal!
Batteries and electronics module must be collected
separately and disposed of in accordance with local
requirements.
Remedy
Adjust hardness range
Replace cartridge
MU1H-1564GE23 R0416

Publicité

Table des Matières
loading

Table des Matières