preparing the boiler for operation

Addressing the system interface

1) Find menu 0 "Network" then confirm with the OK
key. Select sub-menu 03 "Interface system" then
confirm with the OK key.
2) Select sub-menu 030 "Zone number" then
confirm with the OK key and assign a configura-
tion code to the system interface :
- 0 no setting zone (Systeme interface not
assigned to any zone)
- 1 zone 1 setting (Systeme interface assigned to
heating zone 1)
- 2 zone 2 setting (Systeme interface assigned to
heating zone 2)

Configuration of the temperature control by zones

Zone 1
System interface
* The system interface is connec-
ted to the control unit BUS
BridgeNet®.
* Assign configuration code "1"
to parameter 030 on the system
interface.
Room sensor
* The room sensor is connected
to the control unit BUS Bridge-
Net®.
* Refer to the room sensor ins-
tructions to assign it to Zone 1.
Weekly room thermostat
* The weekly room thermostat is
connected to the "TA1" terminal
block on the control unit.

Meaning of the LEDs

GREEN LED (left)
Indicator light off
Indicator light on
Indicator light flashing
GREEN LED (centre)
Indicator light off
Indicator light on
Indicator light flashing
RED LED (right)
Indicator light off
Indicator light on
Zone 2
System interface
* The system interface is connec-
ted to the control unit BUS
BridgeNet®.
* Assign configuration code "2"
to parameter 030 on the system
interface.
Room sensor
* The room sensor is connected
to the control unit BUS Bridge-
Net®.
* Refer to the room sensor ins-
tructions to assign it to Zone 2.
Weekly room thermostat
* The weekly room thermostat is
connected to the "TA2" terminal
block on the control unit.
Main supply OFF
Main supply ON
Main supply ON, operation in manual mode
No BUS BridgeNet® communication
BUS BridgeNet® communication present
BUS BridgeNet® communication initialisation
No operating faults
Presence of one or more operating faults
- 3 zone 3 setting (Systeme interface assigned to
heating zone 3)
then confirm with the OK key.
3)
Carry
out
tion
on
each
(if necessary).
4) Return to the main display by repeatedly pres-
sing the
key
At this stage, the module is operational with the
factory parameters.
Possible configurations (see below).
System interface
* The system interface is connec-
ted to the control unit BUS
BridgeNet®.
* Assign configuration code "3"
to parameter 030 on the system
interface.
Room sensor
* The room sensor is connected
to the control unit BUS Bridge-
Net®.
* Refer to the room sensor ins-
tructions to assign it to Zone 3.
Weekly room thermostat
* The weekly room thermostat is
connected to the "TA3" terminal
block on the control unit.