thermoregolation

Temperature control

Scenario no. 1: the boiler is equipped with a BUS
BridgeNet® connection
The boiler and the control unit communicate for
optimised operation. In this scenario, several types
of temperature control are possible depending on
the configuration and the installation's parameter
settings. Please refer to the boiler instructions.
It is advisable to check that temperature control
is active by ensuring that the corresponding icon is
displayed on the boiler screen. If it is not displayed,
activate the function. The water flow temperatures
for each zone can be perfectly adapted to the spe-
cifications of the installations.
Scenario no. 2: the boiler does not have a BUS
BridgeNet® connection
In this scenario, the control unit cannot perform
temperature control. The water flow temperature
for Zone 1 is defined by the boiler setting. For Zone
2, the module then controls the motorised mixing
valve in order to maintain a fixed water flow tempe-
rature, as defined by parameter 502.
For Zone 3, the module then controls the motorised
mixing valve in order to maintain a fixed water flow
temperature, as defined by parameter 602.