GB
product description
Presentation
The multi-zone heating system management electronic control unit can be used to manage up to three
single-temperature heating zones (direct zone without mixing valve) or multi-temperature heating zones
(mixed zone with mixing valve) as follows:
Single-temperature
1 direct zone
2 direct zones
3 direct zones
The multi-zone heating system management electronic control unit can operate in one of two control
modes based on the type of boiler to which it is connected:
Scenario no. 1: the boiler is equipped with a BUS BridgeNet® connection. The boiler and the control unit
communicate for optimised operation. The control unit and heating can be configured directly on the boi-
ler control panel. They can also be configured using an system interface (option) connected to the BUS
BridgeNet®.
Scenario no. 2: the boiler does not have a BUS BridgeNet® connection option. When a heating request is
sent to the control unit, the signal is transferred to the boiler by a dry contact. An system interface (option)
must then be used to configure the control unit and heating.
Technical data
Model name
Compliance
Thermostatic 3-way mixing valve
Recommended model/
Main characteristics
Circulating pump
Supply Voltage/Frequency
Control unit dimensions (L x H x D)
40
Multi-temperature
1 direct zone + 1 mixed zone
1 direct zone + 2 mixed zones
2 direct zones + 1 mixed zone
Brand
Model
Main supply
Opening/closing time
Connections
Type
Supply voltage
Maximum current
mm
Zone Manager Kit
Honeywell
VC6982-11
230VAC 50/60 Hz
120 seconds
Molex
AC fixed speed
230VAC 50 Hz
0.5 A19
230VAC 50 Hz
230 x173 x 54