DIP-SWITCH FUNCTIONS

T.CH AUTOMATIC
.Automatic closure not enabled
.Automatic closure enabled at 5 sec.
.Automatic closure enabled at 10 sec.
.Automatic closure enabled at 15 sec.
.Automatic closure enabled at 20 sec.
.Automatic closure enabled at 30 sec.
.Automatic closure enabled at 60 sec.
DIP4
ON
when the photocell intervenes during operation blocks movement until disengagement then
continues opening, when the photocell intervenes in closure blocks movement until disengagement then
inverts opening (connecting a normally open NA button gives command PERSON PRESENT)
DIP4
OFF the photocell intervenes only in closure, inverting opening
N.B.
any function variation must be made with the blind closed;
the electrical limit switches, which must be placed in series with the motor phases (open/close) are
automatically detected by the control unit via amperometric control;

FINAL WARNINGS

The installation of the automation must be performed properly by qualified personnel in possession
of legal requirements and in compliance with machine directive 98/37/CE and standards EN13241-1,
EN 12453 and EN 12445.
Check the solidity of existing structures (columns, hinges, doors) in relation to the force generated by
the motor.
Check that there are suitably sturdy mechanical stops at the end of opening and closing travel of the
doors.
Analyze the risks of the automation and adopt necessary safety measures and warnings.
install controls (such as the key selector) so that the user is not in a hazardous position.
Upon completion of installation, check the safety devices several times, as well as those for
signalling and automation release.
Provide the automation with the EC label or tag that contains the danger information and
identification data.
Give the final user the instructions for use, safety warnings and the EC declaration of conformity.
Make sure the user understands proper automatic, manual and emergency operation of the
automation.
Inform the user in writing (for example in the instructions for use) of any unprotected residual risks
and foreseeable improper use.
Provide a maintenance schedule for the system (at least every 6 months for the safeties) with an
appropriate register of work performed.
Keep this instruction manual for future reference.
KEY Automation Srl reserves the right to make, at any time, any modifications which may be
required to improve appearance and/or operation.

DISPOSAL

This product is composed of various components which may in turn contain pollutants. Do not dispose of it in
the environment! Find out about the method for recycling or disposing of the product in compliance with
current local laws.
11
DIP1
DIP2
DIP3
OFF
OFF
OFF
ON
OFF
OFF
OFF
ON
OFF
ON
ON
OFF
OFF
OFF
ON
OFF
ON
ON
ON
ON
ON