Sonnenkonig GENUA Mode D'emploi page 45

Masquer les pouces Voir aussi pour GENUA:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Correct working check
After the fan installation switch on the current and switch on the fan. Control the blade ro-
tation and the solidity: if the fan swings excessively switch off the fan, disable the current
and perform the following controls:
• Unloose the screws
• Control if the distance between the four blade terminals are equal (see igure below)
• Twist again the screws
• Control the distance between the ceiling and the extremity of each one of the four
blades. It must be equal.
• Switch on the fan and verify the correct working
• In case of further incorrect working repeat from point one, or contact an electrician.
Models equipped with fastning hook
Warning: Apply to a qualiied electrician for installation in case you are not knowledge-
able about electrical wiring.
• Push the lower and upper canopies onto the down rod.
• Run the supply cord up through the centre hole of the down rod.
• Fix the down rod onto the bracket at the motor head with rivet, cotter pin and set
screw provided.
• Slide down the lower canopy and ix it to the lower end of the down rod using set
screw provided.
• Hang the fan onto the suspension hook. (not supplied)
• Connect the power cable to the outlet box (connection diagram as shown in ig.2)
• Slide up the upper canopy and ix it with set screw.
• Mount the blades onto the fan motor with proper bolts and washers.
1. Steel frame ceiling
2. Hook nut
3. Spring washer
4. Washer
5. Threaded hook (not supplied)
6. Power cable
7. Down rod Fig. 3-2
8. Wooden ceiling beam
9. Wood hook (not supplied) Fig. 3-3
10. Concrete ceiling
11. Steel fram
12. S. hook