Technical Data - WAGNER WallPerfect Flexio 585 I-Spray Traduction Du Mode D'emploi Original

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

GB
Problem
Poor covering
capacity on the wall
Device does not
function

24. technical Data

Max. viscosity (Interior wall paint/WallPerfect
I-Spray spray attachment):
Power source:
Power consumption:
Atomizing output:
Max. flow rate (Interior wall paint/WallPerfect
I-Spray spray attachment):
Double insulation:
Sound pressure level*:
Sound pressure output*:
Oscillation level**:
Weight:
* Measured in accordance with EN 50144-2-7:2000
** Measured in accordance with EN 60745-1
information about the oscillation level
The specified oscillation level has been measured according to a standard test
procedure and can be used to compare against electric tools.
The oscillation level is also for determining an initial assessment of the vibrational
strain.
Attention! The vibration emission value can differ from the specified value when the
electric tool is actually in use, depending on how the electric tool is being used. It is
36
Cause
Spray material is too cold
Highly absorbent surface or paint
with poor covering capacity
Distance too large
Device overheated
technical Data
Flexio 585 I-Spray
remedy
The material you are
spraying should be at
room temperature
Cross spray (Fig. 11)
Closer to the object
Unplug the power
plug, let the device
cool down approx. 30
minutes, check the air
filter, do not cover the
intake slots
4000 mPas
230-240 V
, 50 Hz
~
630 W
25 W (min), 200 W (max)
500 ml/min
74 dB (A); Uncertainty K = 4 dB
87 dB (A); Uncertainty K = 4 dB
< 2.5 m/s; Uncertainty K = 1.5 m/s
1.9 kg