GB
Problem
Poor covering
capacity on the wall
Device does not
function
24. technical Data
Max. viscosity (Interior wall paint/WallPerfect
I-Spray spray attachment):
Power source:
Power consumption:
Atomizing output:
Max. flow rate (Interior wall paint/WallPerfect
I-Spray spray attachment):
Double insulation:
Sound pressure level*:
Sound pressure output*:
Oscillation level**:
Weight:
* Measured in accordance with EN 50144-2-7:2000
** Measured in accordance with EN 60745-1
information about the oscillation level
The specified oscillation level has been measured according to a standard test
procedure and can be used to compare against electric tools.
The oscillation level is also for determining an initial assessment of the vibrational
strain.
Attention! The vibration emission value can differ from the specified value when the
electric tool is actually in use, depending on how the electric tool is being used. It is
36
Cause
•
Spray material is too cold
•
Highly absorbent surface or paint
with poor covering capacity
•
Distance too large
•
Device overheated
technical Data
Flexio 585 I-Spray
remedy
The material you are
➞
spraying should be at
room temperature
Cross spray (Fig. 11)
➞
Closer to the object
➞
Unplug the power
➞
plug, let the device
cool down approx. 30
minutes, check the air
filter, do not cover the
intake slots
4000 mPas
230-240 V
, 50 Hz
~
630 W
25 W (min), 200 W (max)
500 ml/min
74 dB (A); Uncertainty K = 4 dB
87 dB (A); Uncertainty K = 4 dB
< 2.5 m/s; Uncertainty K = 1.5 m/s
1.9 kg