Manual Activation Of The Pellet Loading System; Alarm Management - Royal DORA AIR Notice D'installation Et D'entretien

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

14.6 Manual activation of the pellet loading system

Upon first ignition, or if the tank is completely empty, once the pellets have been loaded into the
tank, it is possible to manually activate the loading system so that the pellets fill the circuit correctly:
a) Use the arrow keys
b) Select the password "7" with the
c) Select the submenu
d) Select password "54"
e) Hold down the key
It is only possible to activate this procedure with the stove off and completely cold.

15 ALARM MANAGEMENT

If an anomaly occurs in the operation, the following procedure is activated:
1)
acoustic alarm (beep);
2) one of the following system LEDs lights up:
3) if the anomaly concerns an error, the stove will switch off.
Press and hold the
"cancel" key to display the error code:
CODE
ERROR/WARNING
E001
Defective control panel
Remote control communication
E002
signal error
E004
Communication error
Ignition failure error
E101
E105
Pellet probe alarm
E108
Pressure or thermal safety error
E106
Temperature probe malfunction
E110
Temperature probe malfunction
E111
Fume probe malfunction
Scheduled maintenance notification
A002
(flashing icons)
A004
Low battery
A005
Hall sensor malfunction
----
Stove cleaning
----
Ignition failure error
90
to go to the set-up menu
key and confirm with the
[31]
and confirm with the
to activate the manual loading system.
DESCRIPTION
and press the key
key;
key;
;
POSSIBLE CAUSES
Defective control panel
Defective control panel
Connection cable between board and control
panel interrupted or disconnected.
If it appears during the configuration change,
ignore this error
Insufficient pellets
Pellet quality
Faulty ignition system
Dirty burn pot
Pellet probe disconnected or faulty
Dirty fume evacuation system
Worn sealing gaskets
Insufficient combustion air
Problems of overheating of the pellet tank
Sensor(s) connected to T01 (ref. wiring
diagram)
Defective air probe
Overheating problems
Sensor(s) connected to T02 (ref. wiring diagram)
Defective air probe
Sensor(s) connected to T03 (ref. wiring
diagram)
Defective flue gas temperature probe
Periodically, the stove requires maintenance by
a specialist technician
The back-up battery (mod. CR2032) on the
electronic board is low *
Hall sensor on fumes fan disconnected or faulty
Combustion chamber, burn pot or dirty fume
evacuation.
Detached or blocked pressure detection tubes.
Blocked combustion air intake.
Faulty ignition resistance
Worn gaskets; Incorrect burn pot position
;
LED
004778391 - 23/09/2021

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Grazia e air

Table des Matières