• The ventilation openings must not be covered over (minimum distance from
other external attachments: 100 mm).
• Follow the platform guidelines (www.manted.de) when installing the system
and establishing the electrical connections.
I
NOTE
After installation of the system, the pre-set parameters on the system software
must be checked (chapter "Configuring the system software" on page 13).
6.2
Removing the roof hatch
Proceed as follows (fig. 6):
➤ Remove all screws and fixings for the existing roof hatch.
➤ Take out the roof hatch.
➤ Remove the sealant around the opening so that the surface is clean and free
of grease.
I
NOTE
Dispose of all waste material, glue, silicon and seals separately. When doing
so, follow the waste disposal requirements applicable in your local area.
6.3
Preparing the unit fixings
➤ Drill out the 8 factory-made holes to a diameter of 8.5 mm (fig. 7).
6.4
Preparing the unit (RTX1000/2000 only)
A
NOTICE!
When preparing the unit on the work surface, make sure it is secured against
falling off.
Make sure that the work surface is clean and level to ensure that the unit is not
damaged.
Proceed as follows (fig. 8):
➤ Place the parking cooler on a work surface with the casing facing down.
➤ Screw the 8 self-tapping M8 threaded plugs into the blind holes marked "1".
To do so, use the 1/4" bit supplied.
➤ Screw the 4 self-tapping M6 threaded plugs into the blind holes marked "7".
Use a 5 mm hexagon bit to do so.
EN
Installation
9