Technical Data - Geberit HyTronic Mode D'emploi

Masquer les pouces Voir aussi pour HyTronic:
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 39

Technical data

Technical data
Mains-operated HyTronic urinal flush control
Interval flush factory setting
Interval flush adjustment range
Flow rate at 1 bar
Test pressure water
Test pressure air / inert gas
Detection time factory setting
Detection time adjustment range
Frequency
Power consumption
Protection degree
Nominal voltage
Operating voltage
Flush time factory setting
Flush time adjustment range
Humidity
Press Op Range
Operating temperature water max.
Battery-operated HyTronic urinal flush control
Interval flush factory setting
Interval flush adjustment range
Flow rate at 1 bar
Test pressure water
Test pressure air / inert gas
Battery lifetime Lithium
Battery lifetime Alkaline
Detection time factory setting
Detection time adjustment range
Battery type
Power consumption
Protection degree
Operating voltage
Flush time factory setting
Flush time adjustment range
Humidity
Press Op Range
Operating temperature water max.
38
24 h
1 - 168 h
0.3 / 0.24 (with flow limiter) l/s
16 bar
3 - 15 s
50 - 60 Hz
< 0.5 W
IP 45
110 - 240 V AC
4.5 V DC
3 - 15 s
< 100 % relative
1 - 8 bar
30 °C
24 h
1 - 168 h
0.3 / 0.24 (with flow limiter) l/s
16 bar
~ 2 years
~ 1.5 years
3 - 15 s
Lithium 1.5 V (AA)
< 0.5 W
IP 45
3 - 15 s
< 100 % relative
1 - 8 bar
30 °C
3 bar
7 s
4 s
3 bar
7 s
3 V DC
4 s

Publicité

Table des Matières
loading

Table des Matières