Trouble-shooting list
Fault
Cause
Not heating up.
– No operating
voltage.
Taking an ex-
– Heating element
tremely long time
furred.
to heat up in
230 V operation
If this does not solve the problem, please contact the Truma
Service.
10
Technical data
determined in accordance with Truma test conditions
Rectification
Water content
– Restore power
5 litres
supply.
Operating pressure
max. 1.2 bar (only use pump without non-return valve)
– Descale water
Power supply
system (see
230 V ~, 50 Hz
maintenance).
Power consumption
1.3 A (300 W)
Thermal cut-out
65 °C
Over-temperature protection
85 °C
Heating time from approx. 15 °C to approx. 60 °C
approx. 50 minutes
Weight (without contents)
2 kg complete with drain and venting valves
Dimensions
length 37 cm, height 23 cm, width 22 cm
Conformity Declaration
The Therme complies with the requirements of EN 60335,
EMC directive 89/336/EEC, low voltage directive 73/23/EEC
and the associated standards and technical specifications,
and is therefore entitled to bear the CE symbol.
The right to effect technical modifications is reserved!