Trouble-Shooting List; Technical Data - Truma Therme 230 V Mode D'emploi

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 12

Trouble-shooting list

Fault
Cause
Not heating up.
No operating
voltage.
Taking an ex-
Heating element
tremely long time
furred.
to heat up in
230 V operation
If this does not solve the problem, please contact the Truma
Service.
10

Technical data

determined in accordance with Truma test conditions
Rectification
Water content
Restore power
5 litres
supply.
Operating pressure
max. 1.2 bar (only use pump without non-return valve)
Descale water
Power supply
system (see
230 V ~, 50 Hz
maintenance).
Power consumption
1.3 A (300 W)
Thermal cut-out
65 °C
Over-temperature protection
85 °C
Heating time from approx. 15 °C to approx. 60 °C
approx. 50 minutes
Weight (without contents)
2 kg complete with drain and venting valves
Dimensions
length 37 cm, height 23 cm, width 22 cm
Conformity Declaration
The Therme complies with the requirements of EN 60335,
EMC directive 89/336/EEC, low voltage directive 73/23/EEC
and the associated standards and technical specifications, and
is therefore entitled to bear the CE symbol.
The right to effect technical modifications is reserved!

Publicité

Table des Matières
loading

Table des Matières