USE
Pedestrian opening operation
0,5 s
>1 s
Sequential mode operation
Semi-automatic mode operation
Specific operating modes
Operation with a Telis type remote control
Operation with photoelectric cells
The photoelectric cell operation mode can be programmed during installation, as follows:
•
photoelectric cell mode activated for closing only: if an obstacle is detected when closing, the gate stops and reopens.
•
photoelectric cell mode activated for opening and closing:
- on opening: if an obstacle is detected, the gate stops then continues to open once the obstacle obstructing the cells
has been removed.
- on closing: if an obstacle is detected, the gate stops then reopens once the obstacle obstructing the cells has been
removed.
Operation with a blinking orange light
The orange light is switched on when the gate moves. An advance warning that starts three seconds before gate motion
begins can be programmed during installation.
Operation in automatic closure mode
In automatic closure mode, the gate will close automatically after the time delay programmed during installation.
Pressing the button before the end of the time delay will close the gate.
Operation with an emergency battery backup (FX24)
If an emergency battery backup is installed, the motor will continue to operate even if mains power is lost.
The motor drive unit operates in the normal way. The safety features remain active.
Battery charge time: 12/14 hours.