Geberit Mapress 2 Mode D'emploi page 41

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 43
Operating instructions for Mapress pressing collar and adapter for pressing collar
5
Press in the locking pin (1), pull the pressing collar apart and
remove it (2)
CAUTION
Leaky connection due to failed pressing sequence
Ensure that the pressing collar is completely closed after the
pressing sequence
Have any pressing collars that have not closed completely as
well as the adapter for pressing collar and the pressing tool
inspected for damage by an authorized repair shop. Replace any
connections that have not been pressed correctly (do not
attempt corrective pressing)
If there are any burrs on the pressfitting after the pressing
sequence, have the pressing collar and the adapter for pressing
collar inspected by an authorized repair shop
2
1
2
EN