Operating instructions for Mapress pressing collar and adapter for pressing collar
5
Slide the locking lug over the locking pin until it snaps into place and
the pressing collar firmly surrounds the fitting
6
Turn the pressing collar into the pressing position
7
Make sure that the release lever and locking lug form a line
Hooking the adapter for pressing collar into the pressing collar
(up to ø 88.9 mm)
Prerequisites
Pressing collar is positioned.
WARNING
Risk of injury caused by flying fragments if adapter for
pressing collar is used incorrectly
Make sure that the claws of the adapter for pressing collar
always completely embrace the pins of the pressing collar
Do not remove or twist the pressing collar after interrupting the
pressing sequence.
1
To open the adapter for pressing collar, push both jaw levers
together (1)