9.3
venturi adjustment
This appliance has an air shutter that has been factory set open according to
the chart below:
Regardless of venturi orientation, closing the air shutter will cause a more
yellow flame, but can lead to carbonization. Opening the air shutter will cause
a more blue flame, but can cause flame lifting from the burner ports. The flame
may not appear yellow immediately; allow 15 to 30 minutes for the final flame
colour to be established.
AIR SHUTTER ADJUSTMENT MUST ONLY BE DONE BY A QUALIFIED
INSTALLER.
note:
It is important that the orifice is securely inserted into the venturi.
HDX52-2
NG
3/8" (9.5mm)
P
7/16" (11mm)
9.4
fl ame characteristics
It's important to periodically perform a visual check of
the pilot and burner flames. Compare them to the
illustration provided. If any flames appear abnormal,
call a service person.
MAXIMUM INPUT RATE
NG
55,000 BTU/HR
P
3/8" - 1/2"
(9.5mm - 12.7mm)
adjustments
VENTURI
BURNER
AIR
SHUTTER
OPENING
ORIFICE
PILOT
ELECTRODE
BURNER
FLAME
SENSOR
FLAME MUST ENVELOP
UPPER 3/8" (9.5mm) TO 1/2"
(12.7mm) OF FLAME SENSOR
W415-2363 / A / 11.01.19